- ¼öÁú°èÃø±â
- À¯·®°è ¼öÀ§°è
- ½Ã½ºÅۺоß
- BEMS/FEMS
|
|
|
|
|
|
|
CL7685.010-CL7901 |
|
|
B&C |
¹®ÀÇ¿ä¸Á |
|
|
|
|
|
DPD ¹ý°ú °°Àº ½Ã¾àÀÌ ÇÊ¿äÇÏÁö ¾ÊÀ½, À¯Áö °ü¸®°¡ °£´ÜÇϸç Á¤¼öÀåÀÇ ÀÜ·ù¿°¼Ò¸¦ Á¦¾î¿ëÀ¸·Î ÃÖÀû |
|
|
|
Drinking Water, Water Treatment, Bottling Water |
|
|
|
Residual Chlorine Meter (CL7685.010) |
Ç¥½ÃºÎ |
6 character alpha-numeric LCD with back light |
ÃøÁ¤ ¹üÀ§ |
0 ~ 2.000 ppm, 0 ~ 20.00 ppm, 0 ~ 200.0 ppm Áß ÅÃ1 |
Input Current |
160 nA/ppm @ 20¡É |
Zero Adjustment |
¡¾ 200 nA |
Cell Sensitivity |
12.5 ~ 250 % * Polarization : -200 mV (0 ~ -1250 mV) * Temperature Coefficient : 0 ~ 4%/¡É * Filter Software 90% RT : 0.4 ~ 50.0 sec for small/large variation |
Temperature |
Pt100 §Ù 3 wire * Measuring & Compensation Range : -2 ~ +52 ¡É * Resolution : 0.1 ¡É * Zero Adjustment : ¡¾ 1 ¡É |
Àü¼Û Ãâ·Â |
Isolated 4~20 mA, (Max. 600§Ù) |
¸±·¹ÀÌ Ãâ·Â |
Two SPDT, 5 amp, 230 VAC resistive, with programmable setpoints |
¸±·¹ÀÌ Ãâ·Â ±â´É |
Programmable on/off, pulse width modulation (PWM) or pulse frequency modulation (PFM) |
°æº¸ ¸±·¹ÀÌ |
One SPDT, 5 amp, 230 VAC resistive, with programmable setpoints |
ÀçÁú/º¸È£ µî±Þ |
Transmitter : NEMA 1 panel mount standard Transducers : Encapsulated dual frequency sensor heads, encased in stainless steel shrouds with integral transducer clamps and BNC connectors |
Å© ±â |
96(H) ¡¿ 96(W) ¡¿ 155(D) mm (Cutout : 92¡¿92 mm) |
»ç¿ë Á¶°Ç |
Operating Temperature Electronics: -20 ~ 50¡ÆC, Sensor : 0 ~ 50¡ÆC, Operating Humidity : 0 ~ 99% non-condensing |
Àü ¿ø |
AC120/230V, 50/60 Hz |
¼ÒºñÀü·Â |
Max. 5 VA |
|
|
|
|
|
|
Ç° ¸í |
: |
Residual Chlorine Meter |
|
¸ð µ¨ |
: |
CL7685.010 |
|
Á¦Ç°»ç¾ç |
|
|
|
|
|
|
Ç° ¸í |
: |
Residual Chloline Sensor |
|
¸ð µ¨ |
: |
CL7901 |
|
Á¦Ç°»ç¾ç |
|
|
Residual Chlorine Sensor (CL-7901) |
ÃøÁ¤ ¹æ¹ý |
Æú¶ó·Î±×·¡Çȹý¿¡ ÀÇÇÑ ¹«½Ã¾à ÃøÁ¤ |
ÃøÁ¤ ¹üÀ§ |
0 ~ 200 ppm |
À¯Ã¼ÀÇ ÃøÁ¤È¯°æ |
pH 8 ÀÌÇÏ |
¹ÝÀÀ ¼Óµµ |
90% in 60 sec |
ħÀûºÎÀçÁú |
Noryl and 316 Stainless Steel |
»ç¿ë ¿Âµµ |
0 ~ 50¡ÆC |
ÄÉÀ̺í |
7 m (Std) (ÁÖ¹®»ç¾ç :ÃÖ´ë 30m) | |
|
|
|
Ç° ¸í |
: |
Residual Chloline Sensor Cable |
|
¸ð µ¨ |
: |
CL25FT |
|
Á¦Ç°»ç¾ç |
|
|
|
|
|
|
Ç° ¸í |
: |
Sensor Accessory |
|
¸ð µ¨ |
: |
MB10 |
|
Á¦Ç°»ç¾ç |
|
|
|
|
|
|
Ç° ¸í |
: |
Residual Chloline Sensor Holder |
|
¸ð µ¨ |
: |
CL7901HL |
|
Á¦Ç°»ç¾ç |
|
|
Residual Chloline Sensor Holder (CL7901HL) |
Àç Áú |
Clear cast acrylic |
À¯ÀÔ/ À¯Ãâ |
Inlet 1/4" id tubing bard (1/8" FNPT in flowcell) Drain 1/2" id tubing hose barb (3/8" FNPT in flowcell) |
À¯ ¼Ó |
0.5 LPM ~ 2 LPM | |
|
|
|
|
|
|